SPECIFICATIONS
1 TOB-BTS-60V50A Battery Pack test system is mainly used for Electric Car battery pack testing, it can test lithium battery pack voltage up to 60v with Max current 50A.
2 It can also test battery pack with protect board (PCB/PCM)
Project index |
Parameter index |
|
Input Power |
AC 380V ±10% / 50Hz |
|
Resolution |
AD: 15bit; DA: 12bit |
|
Input Resistance |
≥ 1 MΩ |
|
Input Power |
7848 W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Voltage Range |
Charge: 300mV~60V; Discharge: 2.5V~60V |
Discharge Min Voltage |
2.5 V |
|
Accuracy |
± 0.1% of FS |
|
Stability |
± 0.1% of FS |
|
Current |
Per Channel Current Range |
250 mA~50 A |
Accuracy |
± 0.1% of FS |
|
Stability |
± 0.1% of FS |
|
Power |
Per Channel Output Power |
3000W |
Stability |
± 0.2% of FS |
|
Time |
Current Response Time |
The Current rise Response Time is 20 ms |
Step Time Range |
1 s ≤ Single Step Time Range ≤ 365*24 h, Time Form Support 00:00:00(h.min.s) |
|
Data Recording |
Record Condition |
Lower sampling time: 100 ms |
Lower sampling Voltage: 150 mV |
||
Lower sampling Current: 5 mA |
||
Record Frequency |
10 Hz |
|
Charge |
Charge Mode |
Constant Current Charge, Constant Voltage Charge, Constant Current and Constant Voltage Charge |
End Conditon |
Voltage, Current, Relative Time, Capacity |
|
Discharge |
Discharge Mode |
Constant Current Discharge |
End Condition |
Current, Current, Relative Time, Capacity |
|
Cycle |
Loop Measure Range |
1~65535 times |
Per Loop Step No. |
254 |
|
Nested Loop |
Nested loop Function, Max Support 3 Layers |
|
Protection |
Software Protection |
Power-down Data Protection |
Off-line Testing Function |
||
Setting Protection Condition, Setting Parameter: Voltage Low limit, Voltage Upper limit, Current Low limit, Current Upper limit, Delay Time |
||
Hardware Protection |
Addition Avoiding Reverseconnection Protection Model |
|
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
< 80 dB |
|
Database |
My SQL Databace |
|
A Means of Communication of Upper Machine |
TCP/IP Protocol |
|
Data Output |
EXCEL, TXT, Graph |
|
Operation system |
Offioce 2010 , Win 7 system |
|
Communication Interface |
Ethernet Port |
|
Per Unit Main Channels No. |
1 |
|
Dimensions |
18U, W*D*H: 606*606*990 (mm) |
Machine accessories