SPECIFICATIONS
Project index |
Parameter index |
|
Input Power |
AC 220V ±10% / 50Hz |
|
resolution |
AD: 16 bit; DA: 16 bit |
|
Input Resistance |
≥ 1 MΩ |
|
Input Power |
425 W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Constant voltage range |
25 mV~5V |
Discharge Min Voltage |
The end of clamps can discharge to 1V, and the wire length of 2m can discharge to 1.5V |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Current |
Per Channel Current Range |
Range 1: 0.5mA-0.1A Range 2: 0.1A-3A Range3: 3A-6A |
Accuracy |
± 0.05% of FS |
|
Constant voltage cutoff current | Range 1: 0.2mA Range: 6mA Range 3: 12mA | |
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
30 W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time |
<1ms |
Step Time Range |
≤ (365*24) hour/step, Time Form Support 00:00:00(h.min:s.ms) |
|
Data Recording |
Record Condition |
Minimum Time Interval: 100 ms |
Minimum Voltage Interval: 10 mV |
||
Minimum Current Interval: Range 1: 0.2mA Range 2: 6mA Range 3: 12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge, Constant Voltage Charge, Constant Current and Constant Voltage Charge, CPC |
End Conditon |
Voltage, Current, Relative Time, Capacity, -△V |
|
Discharge |
Discharge Mode |
CCD、CVD, CPD, CRD, Constant Current and Constant Voltage Discharge |
End Condition |
Voltage, Current, Relative Time, Capacity、 |
|
Pulse |
charge |
CCC, CPC |
Discharge |
CCD, CPD |
|
Min Pulse Width |
500 ms |
|
Pulse Number | A single pulse step supports 32 different pulses | |
Automated Switch |
Automated swith from charge to discharge for each pulse |
|
End Condition |
Voltage, Test Time |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
Power-down Data Protection |
Off-line Testing Function |
||
Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time |
||
Hardware Protection |
Additional Anti-reverse Protection Model |
|
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
< 55 dB |
|
Database |
MySQL Database |
|
A Means of Communication of Upper Machine |
TCP/IP Protocol |
|
Data Output |
EXCEL, TXT |
|
Communication Interface |
Ethernet Port |
|
Per Unit Main Channels No. |
8 |
|
Dimensions |
3U, 482*508*378 (mm) |
PRODUCT DISPLAY
PACKAGE FOR BATTERY TESTER